Methods for Maintaining Dental Treatment Chairs
Dental treatment chairs are essential equipment for dentists to treat patients, which is why they have a high utilization rate. They are also integrated devices that combine air, water, and electricity. Regular maintenance directly affects the lifespan and operational efficiency of the equipment. Therefore, the daily maintenance of dental treatment chairs is particularly important.
Dental treatment chair, because the dental comprehensive treatment chair is the equipment needed by dentists to treat patients..Therefore, the utilization rate is very high..It is also an integrated device for gas..Water..Electricity. Daily maintenance is directly related to the lifespan of the equipment and the rate of equipment integrity..Therefore, the daily maintenance of the dental treatment chair is particularly important.
Dental treatment chair.First is the maintenance of the handpiece..The handpiece is a key component of the dental comprehensive treatment chair. During use,.to avoid cross-infection between patients,.the handpiece needs to be sterilized at high temperature and pressure. To extend the lifespan of the handpiece,.special attention should be paid to daily maintenance.
Dental treatment chairBefore the first use,.drip 1 to 2 drops of high-speed lubricating oil into the shaft using a syringe. Generally,the front of the chair should be cleaned with a cleaning lubricant once a day..The micro-bearing should be cleaned every 2 weeks after working. Maintain normal working pressure of 0.2 to 0.25 MPa when there is no water..The handpiece should not run empty.Otherwise, it will damage the bearing. When the needle is dull,.replace it in time..Otherwise, it will affect the lifespan of the bearing..The maintenance of the treatment machine mainly includes the maintenance of the gas and water circuits. After work every day, the gas should be turned off..Electricity. It is particularly worth mentioning that
2.Dental treatment chairafter turning off the gas,.Water..the gas in the cavity should be discharged using a three-use spray gun,.to avoid the pipeline being in a high-pressure state for a long time,.which can easily lead to aging and cracking. Regularly clean the water filter according to the local water quality..Regularly drain the accumulated water in the air filter pressure reducing valve..: timely clean the suction device and saliva suction device..Regularly take clean waterto clean the pipeline. It is also particularly important to note that.the water pressure and air pressure must be within the specified range,.to avoid sudden rupture of the filter and pipeline..: The operating light and viewing light should not be frequently turned on and off,.as it will shorten the lifespan of the bulbs.3,.Maintenance of the patient chair.
The transmission components should be checked regularly.Dental treatment chair.Lubricating oil should be added regularly to the mechanical transmission position. The hydraulic transmission should regularly check the oil level and quality in the oil tank..When the oil level is insufficient or the oil quality is poor,.it should be replenished and replaced in time. Pay attention to adjust the tightness of the belt in the belt drive..当油量不足或油质量不好时.应及时补充和更换。注意调整皮带传动中皮带的松紧